click for the big picture
click for the big picture
202 cfm port from 3-16-02
Flow in cfm @ 28" water corrected

.1     .2     .3     .4     .5     .6     .7     .8

64    116   147  170  185  193  197   202
Flow in cfm @ 28" water corrected

.1     .2     .3     .4     .5     .6     .7     .8

64    114   147  169   186  196  203   206
Helped at high lifts above .500"
Flow in cfm @ 28" water corrected

.1     .2     .3     .4     .5     .6     .7     .8

65    119  150   174   192  202  205   208
Flow in cfm @ 28" water corrected
6067-"E" RPM published

.1     .2     .3     .4     .5     .6     .7     .8

58    106   140  175   191  200  207  207
This and the previous steps helped mid lift flow from
.2"  to .6" lift dramaticaly. This is good for street heads
low lift figures are somewhat
inflated because of poor valve to
seat sealing